Endodontology focuses on the study of the structure, function, and health of the dental pulp and the surrounding periradicular area, including the prevention and treatment of injuries and diseases. The primary disease addressed in this field is apical periodontitis, which is caused by infection.
One critical step in performing root canal treatment is determining the working length (WL).[1-2] The recommended methods for measuring WL include electronic and radiographic techniques. Accurately establishing and maintaining the WL during cleaning and shaping procedures is essential for successful endodontic treatment.[3-6]
Obtaining an accurate WL is vital for the success of endodontic therapy.[7-8] Failure to identify this key measurement can lead to adverse treatment outcomes, such as increased patient discomfort, potential infection or cyst formation, and the unintended extrusion of intracanal medication into the periradicular tissue.[9,6].
Given the significance of WL in endodontic treatment, the procedure for its establishment should be performed with skill, using techniques that have been proven to give valuable and accurate results and by methods that are practical and efficacious [1,9,10]. A variety of methods have been used for the accurate determination of the working length [6,10,12,13,14,16,17,18], which is considered to be a stage of major importance in endodontic treatment [11,13]. The accuracy of WL determination is affected by several factors, so a combination of methods has been recommended for determining the best WL [4].
In a study of 90 teeth with 129 root canals, it was concluded that the tactile sensation method may provide an accurate determination of WL in teeth with open apices [10]. In a comparative study, Radiovisiography (RVG) was not found to be significantly better than X-ray [11]. RVG was reported to be as good as E-speed film for the determination of file length adjustment when a size 10 file was used. [8]
The radiographic technique of WL determination appears to be a highly acceptable method among dentists [19,20]; however, observer bias in radiographic interpretation may lead to errors [1]. A review showed that the paralleling technique is the recommended exposure technique for radiographic WL determination [4]. The radiographic method described by Ingle is one of the most common and reliable methods used in determining WL [1, 5,6]. Ingle's method depends on estimating the distance between the file tip and the radiographic apex and adjusting it until the file tip is 0.5-1 mm short of the radiographic apex. [7]. However, accuracy is challenging to achieve in this technique because the apical constriction cannot be accurately identified radiographically [17]; and the variables in the technique, such as angulation and exposure, distort this image and lead to errors due to laterally situated foramina [2,3].In addition, there is a radiation hazard both to the patients and the dental personnel. Determining working length with preoperative radiographs without the need for a second radiographic exposure should be explored.
Various root canal determination techniques have been used to determine the root canal length of primary teeth in an in vivo study [12]. Various studies have assessed and compared various methods of working length determination [10,13,14, 17,18]. However, there is a paucity of studies comparing conventional and digital radiographic methods of working length determination. Hence this study sought to compare conventional and digital radiographic methods of working length determination.
This was a comparative study of single-rooted teeth. All single-rooted teeth with single canals that were billed for root canal treatment over the period of the study were utilized for this study.
Preoperative digital radiographs were exposed for all cases using the RVG 6000 system (Kodak Dental Systems, Atlanta, USA) and the working length was determined by measuring
After access, cavity preparation working length was determined using Ingle’s method. A file with a length of 1 mm less (safety factor) than the tooth length as noted from the preoperative radiograph was kept in the root canal and a diagnostic radiograph was taken. On the radiograph, the difference between the end of the file and the apex was measured. This amount was added/subtracted to the original measured length. From this adjusted length of the tooth, 1 mm was subtracted to confirm with the cementodentinal junction. This value was registered as conventional radiographic working length (CRWL).
The working lengths determined by both methods were compared and their levels of coincidence were calculated as done in a previous study [1] as follows:
Exact coincidence: Zero difference between the value obtained by both methods
Acceptable coincidence: 0.5 mm decrease or increase in measurement when compared with that obtained using the conventional radiographic working length (CRWL) method.
Non-acceptable coincidence:>0.5 mm short of or more than the CRWL. The values obtained by the different methods were correlated for levels of coincidence.
All data obtained was analysed using IBM SPSS 26.0. statistical analysis in the form of frequencies, mean and standard deviation was carried out. The means of both methods were compared using a paired sample t-test. Independent t-test was used to compare the means of both techniques across the arches and
A total of 49 patients, comprising 29 males and 20 females with 63 single-rooted teeth indicated for root canal treatment, participated in the study. The participants’ age ranged from 17 to 75 years, with a mean age of 34.59±13.41 years.
The most frequent diagnosis made was acute apical periodontitis and complicated crown fracture, accounting for 30.2% each. The central incisors were the most treated teeth (84.1%) followed by lateral incisors and the maxilla (90.5%) was the most implicated arch (Table 1).
Only 8 (12.7%) cases had exact coincidence while 39 (61.9%) cases had acceptable coincidence. There was an increase in digital radiographic working length compared to conventional radiographic working length in 61.9% of the cases (Table 2).
The mean conventional radiographic working length was 21.49±2.65, while the mean digital radiographic working length was 21.86±2.47. There was a statistically significant association between the means of both methods (P<0.0001). There was a robust positive correlation (r = 0.954) between conventional radiographic working length and digital radiographic working length, and this correlation was statistically significant (p < 0.0001). There was a significant average difference between conventional radiographic working length (CRWL) and digital radiographic working length (DRWL). On average, DRWL was 0.37 points higher than CRWL (Table 3).
Table 4 provides an overview of the central tendency (mean) and variability (Std Deviation) of the measurements for each tooth type. The mean CRWL and DRWL for the central incisor (n = 53) were 21.64±2.37, respectively, while the mean CRWL and DRWL for the lateral incisor (n = 9) were 21.13±3.82. Since there is only one canine measurement, it was not included in the analysis. For CRWL, the p-value was 0.104, indicating no statistically significant difference between central incisors and lateral incisors. For DRWL, the p-value was 0.387, indicating no statistically significant difference between central incisors and lateral incisors.
Accurate determination of the working length is crucial during root canal treatment. Various techniques can be employed for this, including radiographic methods, electronic apex locators, and tactile sensation. [21,22] Many studies have emphasised the importance of precise working length (WL) for the overall success of root canal procedures.[23] This study compared the conventional method of determining working length with a digital technique in single-rooted anterior teeth. Our results showed several statistically significant correlations between the values obtained from both methods. However, these findings differ from another study that found no statistically significant relationship regarding the accuracy of the two techniques.[24] Additionally, several other studies did not identify a strong association between WL values recorded by both methods.[25,26] A survey by Goel TB reported a statistically significant difference between the conventional and digital methods of working length determination.[27] The same study also noted that the traditional method provided better accuracy in measuring working length.[27] The significant results in our study might be due to the clinicians' familiarity with these methods. In our research, central incisors were the most commonly treated teeth, and the maxillary arch was more frequently involved. This aligns with other studies that reported similar findings.
The mean WL recorded with CRWL was 21.49 ± 2.65 mm, while DRWL showed a marginally higher mean of 21.86 ± 2.47 mm. The difference between the two methods (CRWL–DRWL = -0.37 ± 0.80 mm) was statistically significant (p = 0.001). Nonetheless, the size of this difference is less than 0.5 mm, which is within the clinically acceptable tolerance limit of ±0.5 mm for WL determination.[28] This suggests that both CRWL and DRWL are dependable for clinical use.
Furthermore, the strong positive correlation observed between CRWL and DRWL (r = 0.954; p < 0.0001) demonstrates a high level of consistency between the two techniques. This finding aligns with earlier studies that reported no clinically significant differences between digital and conventional radiographic methods for WL estimation. [29]The slightly longer WL values obtained with DRWL may be attributed to the ability to manipulate digital images through magnification, contrast enhancement, and brightness adjustments, which can improve visualisation of apical structures.[31] [32] Clinically, this tendency to slightly overestimate WL may be advantageous, since underestimation poses a higher risk of incomplete canal debridement, whereas minor overestimation rarely leads to over-instrumentation if the apical constriction is respected.
When analysed by tooth type, CRWL and DRWL demonstrated similar trends but with slight variations. For central incisors, the mean WL was 21.64 ± 2.39 mm (CRWL) and 21.13 ± 2.13 mm (DRWL), showing close agreement between the two methods. This may be explained by the relatively straight root morphology and wider canals of central incisors, which facilitate radiographic interpretation. [33]
For lateral incisors, however, CRWL recorded a mean WL of 20.11 ± 3.61 mm, while DRWL recorded a longer mean of 21.90 ± 3.82 mm. The larger discrepancy in lateral incisors could be due to anatomical complexities, including root curvatures and narrower canals, which make radiographic interpretation more challenging. [34] The improved visualisation capabilities of DRWL may help reduce underestimation in such complex cases.
These findings suggest that while both CRWL and DRWL are clinically reliable, DRWL may provide more consistent accuracy in teeth with complex anatomy, such as lateral incisors, owing to its superior image quality and manipulation features.
From a clinical standpoint, both radiographic methods remain valid for WL determination. However, DRWL offers several additional advantages, including reduced radiation exposure, faster image acquisition, and enhanced diagnostic capability. These advantages are particularly valuable in complex endodontic cases where precise WL determination is critical. [35] The overall results of this study therefore support the growing preference for digital radiography in modern endodontic practice.
This study compared the Conventional Radiographic Working Length (CRWL) and Digital Radiographic Working Length (DRWL) methods in determining endodontic working length. The results showed that both methods provided reliable and clinically acceptable values, with a strong positive correlation between them. Although statistically significant differences were observed, the discrepancies were minimal (<0.5 mm) and fell within the accepted clinical tolerance.
When analysed by tooth type, central incisors demonstrated close agreement between CRWL and DRWL, while lateral incisors exhibited slightly greater variation, with DRWL tending to record longer values. These differences may be attributed to anatomical complexities such as root curvatures, which are more common in lateral incisors.
Overall, the findings confirm that both CRWL and DRWL are effective for working length determination. However, DRWL offers additional advantages, including reduced radiation exposure, faster image acquisition, image enhancement capabilities, and potentially greater accuracy in complex root anatomies.
Recommendations
[1] Shanmugaraj M, Nivedha R, Mathan R, Balagopal S. Evaluation of working length determination methods: an in vivo/ex vivo study. Indian J Dent Res 2007;18:60-62
[2] Ingle JI, Bakland LK. Endodontics, 5th ed. Elsevier: Canada; 2002
[3] Katz A, Tamse A, Kaufman Y. Tooth length determination: A review. Oral Surg Oral Med Oral Pathol Oral RadiolEndod1991;72:238-42.
[4] Alothmani OS, Friedlander LT, Chandler NP. Radiographic assessment of endodontic working lebgth. Saudi Endod J 2013;357-64
[5] Katz A, Tamse A, Kaufman AY. Tooth length determination: A review. Oral Surg Oral Med Oral Pathol1991;72:238-42
[6] McDonald NJ. The electronic determination of working length. Dent Clin North Am 1992;36:293-307.
[7] Ingle JI. Endodontic instruments and instrumentation. Dent Clin North Am 1957;1:805-22.
[8] Leddy BJ, Miles DA, Newton CW, Brown CE Jr. Interpretation of endodontic file lengths using RadioVisioGraphy. J Endod1994;20:542-5
[9] Bhatt A, Gupta V, Rajkumar B, Arora R. Working length determination- The soul of root canal therapy: a review. Int J Dent Health Sci 2015;2:105-115
[10] El Ayouti A, Dima E, Lost C. A tactile method for canal length determination in teeth with open apices. Int Endod J 2009;42:1090-5.
[11] Leddy BJ, Miles DA, Newton CW, Brown CE Jr. Interpretation of endodontic file lengths using radiovisiography. J Endod1994;20:542-5.
[12] Wankhade AD, Kumar R, Singh RK, Chandra A. Root canal length determination by different methods in primary teeth: An in vivo study. ped Dent 2013;35:E38-E42.
[13] Diwanji A, Rathore AS, Arora R, Dhar V, Madhusudan A, Doshi J. Working length determination of root canal of young permanent tooth: An in vitro study. ann Med Health Sci Res 2014;4:554-558
[14] Kqiku L, Stadtler P. Radiographic versus electronic root canal working length determination. Indian J Dent Res 2011;22:777-780.
[15] European Society of Endodontology. Quality guidelines for endodontic treatment consensus report of the European Society of endodontology. Int Endod J 2006;39:921-930.
[16] Certosimo FJ, Milos MF, Walker T. Endodontic working length determination—where does it end? Gen Dent 1999;47:281-286.
[17] Sharma MC, Arora V. Determination of working length of root canal. Med J Armed Forces India 2010;66:231-234.
[18] Smadi L. Comparison between two methods of working length determination and its effect on radiographic extent of root canal fillings: a clinical study [ISRCTN71486641]. BMC Oral Health 2006;6:4 doi:10.1186/1472-6831-6-4
[19] Gyorfi A, Suveges I, Ivanyi I, Fazekas A. Determination of working length in General Endodontic practice. Fogoru SZ 2007;100:33-39.
[20] Sede MA, Udoye CI. Endodontic working length determination amongst Nigerian dentists. J Med Biomed Res 2011;10:58-65.
[21] Hoer D, Attin T. The accuracy of electronic working length determination. Int Endod J. 2004;37(2):125–31. doi: 10.1111/j.0143-2885.2004.00764.x. [DOI] [PubMed] [Google Scholar]
[22] Jafarzadeh H, Abbott PV. Ledge formation: review of a great challenge in endodontics. J Endod. 2007;33(10):1155–62. doi: 10.1016/j.joen.2007.07.015. [DOI] [PubMed] [Google Scholar]
[23] Esmaeili, F; Akbari, FA; Zarandi., A. Comparison of accuracy of digital and conventional radiographies in determining endodontic working length. S. Afr. dent. j., Johannesburg , v. 71, n. 9, p. 395-397, Oct. 2016 . Available from <http://www.scielo.org.za/scielo.php?script=sci_arttext&pid=S0011-85162016000900003&lng=en&nrm=iso>. access on 18 Dec. 2024.
[24] Ingle JI, Bakland LK. Endodontic cavity preparation. Textbook of endodontics. 5th ed. Philadelphia: BC Decker; 2002.
[25] Vier-Pelisser FV, Meng A, BenedeteNetto LC, et al. Influence of the instrumentation technique and apical preparation diameter on calcium hydroxide filling in simulated curved canals. Indian J Dent Res 2012;23(6):784–788. DOI: 10.4103/0970-9290.111260.
[26] Dinapadu S, Pasari S, Admala SR, et al. Accuracy of electronic apex locator in enlarged root canals with different root canal irrigants: an in vitro study. J Contemp Dent Pract 2013;14(4):649–652. DOI: 10.5005/jp-journals-10024-1379.
[27] YaghootiKhorasani MM, Ebrahimnejad H. Comparison of the accuracy of conventional and digital radiography in root canal working length determination: An invitro study. J Dent Res Dent Clin Dent Prospects. 2017 Summer;11(3):161-165. doi: 10.15171/joddd.2017.029. Epub 2017 Sep 20. PMID: 29184631; PMCID: PMC5666215.
[28] Sjögren U, Hägglund B, Sundqvist G, Wing K. Factors affecting the long-term results of endodontic treatment. J Endod. 1990;16(10):498–504.
[29] Lucena-Martín C, Robles-Gijón V, Ferrer-Luque CM, Navajas-Rodríguez de Mondelo JM. Accuracy of working length measurement: Electronic apex locator versus conventional radiography. Int Endod J. 2004;37(9):632–636.
[30] Borges BC, Estrela C, Guedes OA, et al. Comparison of working length determination by digital and conventional radiography. Braz Dent J. 2013;24(4):362–366.
[31] Farman AG, Farman TT. A comparison of 18 different x-ray detectors currently used in dentistry. Oral Surg Oral Med Oral Pathol Oral RadiolEndod. 2005;99(4):485–489
[32] White SC, Pharoah MJ. Oral Radiology: Principles and Interpretation. 7th ed. St. Louis: Mosby; 2014.
[33] Kerekes K, Tronstad L. Morphometric observations on root canals of human anterior teeth. J Endod. 1977;3(1):24–29.
[34] Green D. A stereomicroscopic study of the root apices of 400 maxillary and mandibular anterior teeth. Oral Surg Oral Med Oral Pathol. 1956;9(11):1224–1232.
[35] Shemesh H, Cristiani R, Kaufman AY. The accuracy of electronic apex locators and radiographs in working length determination. Oral Surg Oral Med Oral Pathol Oral RadiolEndod. 2005;99(4):499–502.
IJBMR -ISSN: 0976:6685. ©Copyright 2026 This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
Published by BioMedSciDirect Publications