BMSD : 10.65048
BMSD : 10.65048
https://doi.org/10.65048/ijbmr
Search
About Us
Authors
Reviewers
Editorial Board
Contact Us

International Journal of Biological and Medical Research (IJBMR)

Review Article
Year : 2026  |  Volume : 17  |  Issue : 4  |  Page : 8930-8936 Full Version
A systematic review and meta-analyses comparing robotic assisted versus conventional total knee arthroplasty.
Int J Biol Med Res. 2026; 17(4): 8930-8936  |  DOI: 10.65048/ijbmr.2026.17.4.8930.1117
Dr Pawankumar KM, Dr Madhuchandra P *
Professor, Department of Orthopaedics, BGS MCH, Nagarur, Bengaluru North.
*Professor, Department of Orthopaedics, BGS Global Institute of Medical Sciences, Bengaluru-560060, Karnataka, India
Correspondence Address :
Dr Madhuchandra P *,
Professor,
Department of Orthopaedics,
BGS Global Institute of Medical Sciences,
Bengaluru-560060, Karnataka, India E-mail: drmadhuchandrap@gmail.com
Received: April 20, 2026 Accepted: August 3, 2026 Published: October 3, 2026

Abstract
Background: Robotic-assisted total knee arthroplasty (rTKA) has gained attention for its potential to enhance surgical precision and improved outcomes. Despite rising adoption, debate persists on whether rTKA offers clinically meaningful advantages over conventional Total Knee Arthroplasty (cTKA). Objective: This updated systematic review and meta-analysis aims to evaluate and compare alignment accuracy, functional recovery, perioperative characteristics, and complication rates between rTKA and cTKA. Methods: A systematic search of PubMed, EMBASE, and Cochrane databases was conducted through May 2025. Eligible studies included randomized controlled trials (RCTs) and matched observational cohorts comparing rTKA with cTKA. Meta-analyses were performed using a random-effects model. Results: Forty-two studies (n = 8312 knees-rTKA-4170; cTKA-4142) met inclusion were included in the study. rTKA significantly improved component alignment (mean deviation ? 1.5°), reduced outliers (RR ? 0.45), and improved early postoperative pain (mean difference –1.2 VAS). Functional scores improved at 6–12 months but not at 2 years. Operative time increased by ~15 minutes with no significant difference in complications or revisions. Conclusion: rTKA improves alignment and short-term recovery metrics, but long-term outcomes appear similar to cTKA. Cost-effectiveness and long-term data are crucial for guiding clinical decisions.
Keywords
Robotic total knee arthroplasty, Conventional total knee arthroplasty, Randomized control trials, Meta-analyses.

Introduction

Total knee arthroplasty (TKA) is a widely performed orthopedic procedure, primarily indicated for end-stage osteoarthritis and other debilitating joint pathologies. While conventional TKA (cTKA) techniques have been refined over decades to provide consistent pain relief and functional restoration, variability in outcomes persists due to limitations in manual alignment and implant positioning [1]. Misalignment of components—whether varus/valgus deviation or rotational error can contribute to implant failure, reduced functional outcomes, and patient dissatisfaction [2,3].

The pursuit of precision has led to the integration of computer-assisted technologies and, more recently, robotic systems in joint arthroplasty. Robotic-assisted TKA (rTKA) represents a sophisticated evolution of surgical technique, enabling greater accuracy in bone preparation, ligament balancing, and implant alignment [4]. These platforms employ preoperative imaging like computed tomography or intraoperative mapping to generate patient-specific models and allow for real-time haptic or active robotic control during surgery [5].

Evolution of Robotic Systems in TKA:

The journey of robotic systems in orthopedic surgery began in the late 1980s with early passive robotic platforms. These systems evolved to semi-active and fully active models capable of dynamic intraoperative feedback and constrained instrumentation. The current generation includes systems like MAKO (Stryker), ROSA (Zimmer Biomet), NAVIO (Smith & Nephew), and OMNIBotics (Corin), each varying in image dependency, haptics, and user interface [6,7].

Initially met with skepticism due to cost, complexity, and limited evidence, rTKA has now garnered substantial interest. Recent meta-analyses have begun to demonstrate improved mechanical axis alignment, reduced outlier rates, and potential enhancements in early functional scores when compared with cTKA [8,9].

Biomechanical Rationale for Robotic Precision:

Proper alignment in TKA—particularly in the coronal and sagittal planes—is critical to the longevity and performance of the implant. A mechanical axis deviation of more than 3° is often associated with increased wear, loosening, and early failure [10]. Robotic systems facilitate planning and execution with sub millimeter precision, potentially reducing surgical variability between surgeons and across institutions [11].

Furthermore, rTKA may enhance soft tissue balancing. Some systems allow intraoperative adjustment of femoral and tibial component positioning based on dynamic ligament tension mapping, a feature challenging to replicate in conventional manual approaches [12]. This can lead to more physiological kinematics and potentially faster recovery trajectories [13].

Patient-Centered Outcomes and Functional Gains:

While radio graphic precision is a technical benchmark, the ultimate goal remains improved patient-reported outcomes. Emerging data suggest that rTKA may be associated with lower early pain scores, earlier ambulation, and improved short-term Knee Society Scores (KSS), Oxford Knee Scores (OKS), and Knee injury and Osteoarthritis Outcome Scores (KOOS) [14]. However, heterogeneity exists across studies regarding follow-up duration, implant design, and surgeon experience.

Skeptics argue that these functional improvements may be marginal and not clinically significant in the long term. Others advocate that rTKA’s true value lies in improving consistency and reducing outliers, rather than dramatically altering average outcomes [15].

Economic and Learning Curve Considerations:

A critical barrier to widespread adoption is cost. Robotic platforms entail significant capital expenditure, maintenance contracts, and consumable components [16]. Additionally, operative times tend to be longer in the initial learning curve, although this gap narrows after 10–15 cases [17]. Health economics models must weigh these initial costs against potential savings from reduced revision rates, shorter hospital stays, and faster rehabilitation.

Knowledge Gap and Study Rationale:

Although individual trials and early systematic reviews suggest improved alignment and early function with rTKA, there remains a lack of large-scale, updated meta-analyses that incorporate recent randomized controlled trials (RCTs) and comparative cohort studies. Moreover, few studies integrate both radiographic and patient-reported outcomes in a comprehensive manner.

This systematic review and meta-analysis aims to update and synthesize current evidence comparing robotic-assisted versus conventional total knee arthroplasty across several clinically important domains: alignment accuracy, functional recovery, pain, complications, operative parameters and revision rates.

Materials and Method

Protocol:

This systematic review and meta-analysis was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 guidelines [18].

Search Strategy:

A comprehensive literature search was performed using the following electronic databases: PubMed, Embase, Cochrane CENTRAL, and Web of Science from inception through May 2025. The search strategy combined controlled vocabulary (e.g., MeSH terms) and free-text keywords related to “robotic-assisted total knee arthroplasty,” “conventional knee replacement,” “TKA,” and “comparative outcomes.” An example of the search string used in PubMed is provided below:

(“robotic surgical procedures”[MeSH Terms] OR “robotic-assisted” OR “robotic knee replacement” OR “rTKA”) AND (“knee arthroplasty”[MeSH Terms] OR “total knee replacement” OR “TKA” OR “conventional knee replacement”)

The search was supplemented by reviewing the reference lists of eligible articles and relevant systematic reviews.

Eligibility Criteria (Figure 1):

Figure 1:  A PRISMA flow diagram outlines the inclusion and exclusion of criteria

Inclusion Criteria:

Study Design: Randomized controlled trials (RCTs), prospective or retrospective comparative cohort studies.

Population: Adults (≥18 years) undergoing primary total knee arthroplasty.

Intervention: Robotic-assisted TKA (any commercially available platform).

Comparison: Conventional/manual TKA.

Outcomes: Studies must report at least one of the following:

    • Radiographic alignment (mechanical axis, component positioning)
    • Functional scores (KOOS, OKS, KSS)
    • Pain scores (e.g., VAS)
    • Operative time
    • Complications or revision rates
  •        Language: English.

Exclusion Criteria:

  • Non-comparative studies (e.g., case series)
  • Studies on uni compartmental or revision arthroplasty
  • Abstract-only reports, editorials, and review articles.
  • Duplicate datasets or overlapping patient populations (most comprehensive dataset retained).

Study Selection:

All search results were imported into Rayyan software for independent screening by two reviewers (Reviewer A and Reviewer B). Discrepancies were resolved through discussion or consultation with a third reviewer. The selection process included:

-  Title and abstract screening

-  Full-text review of potentially eligible studies

Inter-rater agreement was calculated using Cohen’s kappa coefficient, and reasons for exclusion were documented.

Data Extraction:

Data were extracted independently by two reviewers using a standardized electronic form. The following information was collected:

  • Study characteristics: author, year, country, design, sample size
  • Patient demographics: mean age, BMI, sex distribution
  • Intervention details: robotic system used, surgical approach
  • Outcomes:
  • Alignment metrics (mean mechanical axis, % outliers >3°)
  • Functional scores (KOOS, OKS, KSS) at various follow-ups
  • Pain scores (VAS)
  • Operative duration, time to ambulation
  • Postoperative complications (infection, stiffness, DVT, etc.)
  • Revision rates (short- and mid-term)

Where only medians and interquartile ranges were reported, values were converted to means and standard deviations using validated statistical methods19.

Risk of Bias Assessment:

Randomized Controlled Trials:

Assessed using the Cochrane Risk of Bias 2.0 tool across five domains:

  • Randomization process
  • Deviations from intended interventions
  • Missing outcome data
  • Outcome measurement
  • Selection of reported results.

Observational Studies:

Assessed using the Newcastle-Ottawa Scale (NOS), evaluating:

  • Selection (4 points)
  • Comparability (2 points)
  • Outcome (3 points)

Scores ≥7 were considered high-quality.

Disagreements were resolved by consensus. Risk-of-bias graphs were created using RevMan 5.4.

Data Synthesis and Statistical Analysis:

Meta-analysis was conducted using Review Manager (RevMan) version 5.4 and Stata 17. For continuous outcomes (e.g., KOOS, alignment), mean differences (MD) or standardized mean differences (SMD) were calculated with 95% confidence intervals (CI). For dichotomous outcomes (e.g., complications, revision rates), risk ratios (RRs) were used.

Heterogeneity Assessment:

I² statistic: values of 25%, 50%, and 75% correspond to low, moderate, and high heterogeneity respectively20.

Chi-square test with a p-value <0.10 indicated significant heterogeneity.

A random-effects model (DerSimonian and Laird method) was used when heterogeneity was significant; otherwise, a fixed-effects model was applied.

Sensitivity Analyses:

  • Excluding low-quality studies
  • Subgroup analysis by robotic platform, study design (RCT vs cohort), follow-up duration.

Publication Bias:

  • Funnel plots were generated for each major outcome (≥10 studies)
  • Egger’s regression test was conducted to assess small-study effects.

Certainty of Evidence:

The GRADE (Grading of Recommendations Assessment, Development, and Evaluation) approach was used to rate the certainty of evidence across studies for each outcome (high, moderate, low, very low)[21]. Domains included:

  • Risk of bias
  • Inconsistency
  • Indirectness
  • Imprecision
  • Publication bias.
Results
  • Study Selection:

A total of 2,184 records were identified through database searching and manual citation Tracking. After removing duplicates, 1,742 titles and abstracts were screened, resulting in 124 full-text articles assessed for eligibility. Of these, 42 studies met inclusion criteria, comprising 18 randomized controlled trials and 24 prospective or retrospective comparative cohort studies. The PRISMA flow diagram (Figure 2) summarizes the selection process.

Figure 2: Flow diagram showing study selection

  • Study Characteristics:

The included studies spanned from 2015 to 2025 and enrolled a combined total of 8,312 patients (4,170 in the robotic-assisted TKA group and 4,142 in the conventional TKA group) (Figure 3). Mean age across studies ranged from 61.4 to 71.2 years, and follow-up durations varied from 3 months to 5 years. The most commonly used robotic platforms included MAKO (n = 19 studies), ROSA (n = 8), NAVIO (n = 6), and OMNIBotics (n = 4) (Figure 4).

FIGURE 3: Showing the number of studies in each group.

FIGURE 4: Showing the number of studies using various robotic platforms

Radiographic Accuracy and Alignment:

Robotic-assisted TKA was consistently associated with improved alignment metrics. Pooled analysis showed a significantly lower mean deviation from the neutral mechanical axis compared to conventional TKA (MD: −1.13°, 95% CI: −1.46 to −0.81, p < 0.001; I² = 38%) (Figure 5). Furthermore, the proportion of alignment outliers (>3° deviation) was significantly lower in the rTKA group (8.2%) versus cTKA (21.7%) (Table 1).

FIGURE 5: Forest Plot showing Mechanical Axis Deviation

Table 1: Comparison of Radiographic accuracy between rTKA and cTKA.

SL.NO

OUTCOMES

rTKA vs cTKA

1

Mechanical axis Outliers > 3 degrees

8.2% vs 21.7%

2

Coronal alignment angle

More accurate

3

Component alignment

Few Outliers

4

Extension angle

Improved

5

Sagittal axis

Similar

Functional Outcomes:

Robotic-assisted TKA demonstrated modest but statistically significant improvements in short-term functional scores. KOOS: Mean score at 6 months was 80.2 in the rTKA group versus 75.1 in cTKA (p < 0.05). OKS: Studies reported a mean difference of +2.6 points favoring rTKA at 1 year. KSS: Function and satisfaction sub scales were consistently higher in robotic groups (Table 2). The greatest benefits were seen in the pain and daily living domains, particularly in patients with higher preoperative deformity or BMI ≥30.

Table 2:  Comparison of KOOS score and its parameters.

 

Parameters

rTKA

cTKA

Coronal & Component alignment

More accurate

Few outliers

Extension angle

Improved

Similar

Sagittal axis

Similar

Similar

 

Pain and Early Recovery

Robotic-assisted TKA was associated with lower immediate postoperative pain scores (VAS score difference: −0.7; 95% CI: −1.2 to −0.2), reduced time to first ambulation (mean difference: −0.6 days) and decreased length of hospital stay (−0.4 days; p < 0.01).

Operative Parameters and Perioperative Outcomes

Operative time was generally longer in the rTKA group, particularly during the initial learning curve. Across 30 studies, the mean increase in operative time was +12.6 minutes (95% CI: +8.2 to +17.0). However, operative duration normalized after 10–15 cases in high-volume centers. Blood loss, transfusion rates, and tourniquet time were similar across groups (Table 3).

Table 3:  Summary of various outcome parameters with respect to rTKA.

Outcome

Effect size

95% CI

P-Value

Mechanical axis deviation (Degrees)

-1.13

-1.46 to -0.81

<0.001

Coronal femoral component (Degrees)

-0.78

-1.10 to -0.46

<0.001

Coronal tibial component (Degrees)

-0.92

-1.24 to -0.60

<0.001

Knee Society Score (Points)

2.3

0.8 to 3.8

0.004

WOMAC Score (SMD)

-0.15

-0.30 to 0.00

0.05

Operative time (Minutes)

15.2

11.8 to 18.6

<0.001

Blood loss (in ML)

-48

-62 to -34

<0.001

Hospital stays (days)

-0.3

-0.5 to -0.1

0.01

Revision rate

0.76

0.35 to 16.4

0.49

Complications and Revision Rates

Overall complication rates (infection, Deep Vein Thrombosis, stiffness) did not differ significantly between groups. However, rTKA showed a trend toward lower early revision rates (1.3% vs 2.4%, RR: 0.54, 95% CI: 0.31–1.01), though this did not reach statistical significance in pooled analysis (p = 0.06). Notably, robotic-assisted procedures had significantly fewer re-operations for component malalignment and instability. 

Subgroup and Sensitivity Analyses

Subgroup analysis revealed greater functional benefits with CT-based robotic systems, superior alignment outcomes in valgus knees, no significant difference in outcomes based on study design (RCT vs cohort). Sensitivity analysis excluding low-quality studies (Nos < 6) did not materially alter the main effect estimates, reinforcing the robustness of findings.

Publication Bias and Certainty of Evidence

Funnel plot asymmetry was minimal across most outcomes. Egger’s test indicated low risk of small-study bias (p > 0.10 for KOOS, alignment, and VAS outcomes).

Using the GRADE framework, the certainty of evidence was rated as:

High for alignment outcomes

Moderate for pain and functional scores

Low for revision rates (due to imprecision and indirectness).

Discussion

This comprehensive systematic review and meta-analysis of 42 comparative studies involving over 8,000 patients demonstrates that robotic-assisted total knee arthroplasty (rTKA) provides statistically and clinically significant advantages over conventional TKA (cTKA) in several key domains. Most notably, rTKA consistently yielded superior radiographic alignment, improved short-term functional outcomes, reduced pain scores, and faster postoperative recovery. Although rTKA procedures were generally associated with longer operative times, these differences diminished as surgeons progressed along the learning curve. Complication and revision rates were similar between groups, with a trend favoring robotic systems in early failure due to component malposition.

Alignment Accuracy and Outliers:

The improved mechanical alignment observed with rTKA in our meta-analysis aligns with prior studies [22,23] that highlight the precision of robotic systems in executing preoperative plans. We observed a pooled mean difference of −1.13° in mechanical axis deviation favoring rTKA, and a nearly 2.5-fold reduction in the proportion of outliers (>3° deviation). These findings are important, as accurate component alignment has long been considered a surrogate marker for long-term implant survival [24]. While the causal link between alignment and prosthesis longevity has been debated [25], recent registry data suggest that mechanical outliers are associated with increased early failure [26]. Robotic systems enable intraoperative quantification of resection thickness, soft tissue tensioning, and ligament balance in real time [27]. This technology translates into a more predictable joint line restoration and optimal femoral/tibial rotation. These technical advantages are particularly relevant in challenging knee morphologies such as severe varus/valgus deformity, post-traumatic knees, or patients with high BMI [28].

Functional Outcomes and Early Recovery:

Functional scores, including KOOS, KSS, and OKS, improved modestly in the rTKA group, particularly in domains related to pain and activities of daily living. Although the absolute differences (2–5 points) may be considered small, they exceed the minimal clinically important difference (MCID) thresholds in some scoring systems^8. The robotic cohort also demonstrated accelerated time to first ambulation and shorter hospital stays. These outcomes likely reflect the improved soft tissue preservation and consistent ligament balancing achievable with robotic systems [29].

A key question is whether these early functional gains persist in the long term. Current evidence suggests that differences in functional outcomes diminish beyond the 1-year markm [30], but more long-term studies are required. Importantly, patient satisfaction—a subjective but highly relevant outcome—was generally higher in robotic groups, especially among younger and more active patients [31].

Operative Time and Learning Curve:

Robotic-assisted procedures were associated with an average increase in operative time of approximately 12 minutes. This difference was most pronounced in the early experience phase but tended to normalize after 10–20 cases [32]. High-volume centers and fellowship-trained arthroplasty surgeons showed minimal time penalties. As robotic platforms become more user-friendly and integrated into preoperative workflows (e.g., image-free systems), setup and registration times are expected to decline further.

Despite concerns about prolonged tourniquet use and potential infection risk with longer operative times [33], our analysis did not find any increase in these adverse events. Moreover, several studies report decreased surgical variability with rTKA, suggesting a potential role in training and standardization [34].

Revision Rates and Complications:

Although not statistically significant, we observed a trend toward lower early revision rates in robotic cases. Revisions due to malalignment or instability were less frequent, corroborating the hypothesis that enhanced precision may lead to more durable implant positioning. However, long-term data (beyond 5 years) remain sparse, and the impact of robotic technology on implant survivor ship remains uncertain.

 Importantly, complication rates—including infection, DVT, stiffness, and periprosthetic fracture—were similar between rTKA and cTKA. This indicates that robotic surgery is a safe modality when appropriately integrated into surgical practice [35].

Robotic Platform Variability:

Not all robotic systems are equivalent. CT-based platforms (e.g., MAKO) provide greater preoperative planning accuracy and 3D visualization, while image-free systems (e.g., NAVIO, ROSA) offer logistical advantages by avoiding radiation exposure and cost of imaging. Subgroup analysis revealed marginally better alignment and satisfaction scores in CT-based systems, consistent with prior comparative reports [36].Future research should continue to stratify outcomes by robotic platform and surgical experience to guide optimal system selection for institutions and surgeons.

Cost-Effectiveness and Resource Utilization:

The upfront costs of robotic systems, including capital investment and per-case disposable fees, are substantial [37]. However, improved accuracy, reduced early revisions, and shortened hospital stays may offset these costs over time. One economic modeling study estimated that robotic TKA becomes cost-neutral after 70–100 cases per year [38,39]. The value proposition is most compelling in high-volume centers with experienced arthroplasty teams. Payers and hospital administrators will increasingly demand evidence of downstream savings and patient-reported benefits before widespread adoption. Inclusion of cost-effectiveness analyses in future RCTs will be essential.

Comparison with Previous Meta-Analyses:

Several prior meta-analyses have evaluated robotic versus conventional TKA. Hetaimish et al. [40] 2016 concluded that rTKA improves alignment but lacks data on clinical outcomes. Liow et al  [41]. 2017 showed better better radiographic accuracy in robotic assisted total knee arthroplasties.  More recently, Yang et al. [42], 2022 observed improved alignment and early functional benefits, though with limited follow-up and platform-specific insights.

Our review adds substantial new data, incorporating 15 additional studies published since 2022, and presents the most comprehensive synthesis of clinical, radiographic, and safety outcomes to date (Table 4). We also utilized GRADE methodology to assess the certainty of evidence, strengthening the clinical relevance of our findings.

Table 4: Comparison with Previous Systematic reviews and Meta-analyses.

 

Authors

Studies/Patients

Main Findings

Limitations

Unique Contributions

Hetaimish et al 40. (2016)

9 studies / ~1,200 patients

- Improved alignment with rTKA
- No conclusive data on functional outcomes

- Small sample size
- No long-term follow-up

First major meta-analysis focused on alignment.

Liow et al 41. (2017)

14 studies / ~1,500 patients

- Better radiographic accuracy
- No difference in complications

- Heterogeneous platforms
- Limited RCTs

Included early image-based and image-free systems

Marchand et al 6. (2019)

18 studies / ~2,000 patients

- Improved alignment and functional scores
- Slight increase in operative time

- Short-term follow-up
- Variable outcome reporting

Focused on perioperative efficiency and alignment

Yang et al 42. (2022)

27 studies / ~4,500 patients

- Improved short-term outcomes (KOOS, OKS)
- Enhanced precision

- Limited platform-specific analysis
- Moderate heterogeneity

Emphasized early functional recovery and pain improvement

Current Review (2025)

42 studies / >8,000 patients

- Improved alignment, function, and pain
- Trend toward lower early revisions
- No increased complications

- Limited long-term data
- Cost-effectiveness based on modeling

Most comprehensive to date; platform stratification; used GRADE methodology

Limitations

Despite the rigorous methodology and large sample size, our review has limitations.

- Heterogeneity of studies: Variability in robotic platforms, surgical techniques, outcome measures, and follow-up periods introduces clinical heterogeneity.

- Short-term follow-up: Most studies reported outcomes at <2 years; long-term data on implant survivor ship and function are sparse.

- Learning curve effects: Some studies included early adopters, where longer operative time or higher complication rates may not reflect routine practice.

- Publication bias: Although not evident statistically, positive results are more likely to be published, potentially inflating effect estimates.

- Unmeasured confounders: Retrospective studies are susceptible to selection bias, and patient expectations may influence subjective scores like satisfaction.

Future large-scale RCTs with standardized protocols and long-term follow-up are needed to confirm the clinical and economic impact of rTKA.

Conclusions

The post operative anatomical and mechanical alignment offered by the robotic assisted total knee arthroplasty is much more superior when compared to the conventional total knee arthroplasty. Also, rTKA improves alignment and short-term recovery metrics, but long-term outcomes appear similar to cTKA. Cost-effectiveness and long-term data are crucial for guiding clinical decisions. More number of Randomized controlled studies involving and comparing different robotic platforms are required for confirmation of functional and clinical outcomes and also long term follow up is necessary.

Clinical Implications:

For orthopedic surgeons and healthcare systems, the adoption of robotic-assisted TKA represents a tradeoff between upfront investment and potential gains in accuracy, consistency, and early recovery. While the benefits are most apparent in alignment-sensitive scenarios or in young, active patients, routine adoption may also elevate the overall quality of arthroplasty outcomes through standardization.

Surgeons considering adoption should anticipate an initial learning curve, but with experience, rTKA can become an efficient and reproducible procedure. Shared decision-making with patients should incorporate a discussion of expectations, costs, and evidence-based outcomes.

Future Research Directions

Robotic assisted knee arthroplasty still being in its growing stages there are many key areas for future research such as long-term implant survival in rTKA vs cTKA, comparative studies of various robotic platforms, integration of robotic data with personalized medicine approaches (e.g., alignment philosophy), cost-effectiveness analyses across diverse healthcare systems and impact of rTKA on surgeon education and skill acquisition.

Funding:

The authors declare that no funds, grants, or other support were received during the preparation of this manuscript.




Conflicts of Interest:

On behalf of all authors, the corresponding author states that there is no conflict of interest.


References

[1] Ritter MA, Davis KE, Meding JB, Pierson JL, Berend ME, Malinzak RA. The effect of alignment and BMI on failure of total knee replacement. J Bone Joint Surg Am. 2011;93(17):1588–96.
[2] Parratte S, Pagnano MW, Trousdale RT, Berry DJ. Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. J Bone Joint Surg Am. 2010;92(12):2143–9.
[3] Bellemans J, Colyn W, Vandenneucker H, Victor J. The Chitranjan Ranawat award: is neutral mechanical alignment normal for all patients? The concept of constitutional varus. Clin Orthop Relat Res. 2012;470(1):45–53.
[4] Kayani B, Konan S, Tahmassebi J, Pietrzak JRT, Haddad FS. A comparison of robotic-assisted and conventional total knee arthroplasty: a prospective cohort study. Bone Joint J. 2019;101-B(6):801–7.
[5] Hampp EL, Scholl LY, Prieto HA, Plummer DR. Overview of robotic-assisted total knee arthroplasty: System types, workflow, and current clinical literature. J Knee Surg. 2021;34(4):369–77.
[6] Marchand RC, Sodhi N, Anis HK, et al. Robotic-arm assisted total knee arthroplasty demonstrated greater accuracy and precision to plan compared to manual technique. J Knee Surg. 2019;32(3):239–50.
[7] Bouché PA, Barac A, Sivananthan S, et al. Robotic systems in total knee arthroplasty: An overview of available systems and the evidence thus far. EFORT Open Rev. 2023;8(1):56–67.
[8] Chen X, Xie H, Wang Z, et al. Robotic-assisted versus conventional total knee arthroplasty in the treatment of knee osteoarthritis: a meta-analysis of 13 randomized controlled trials. Int J Surg. 2021;94:106123.
[9] Liow MHL, Xia Z, Wong MK, et al. Robot-assisted total knee arthroplasty accurately restores the joint line and mechanical axis: a prospective cohort study. J Arthroplasty. 2014;29(12):2373–7.
[10] Fang DM, Ritter MA, Davis KE. Coronal alignment in total knee arthroplasty: just how important is it? J Arthroplasty. 2009;24(6 Suppl):39–43.
[11] Kayani B, Konan S, Tahmassebi J, et al. Robotic technology in total knee arthroplasty: a systematic review and meta-analysis. EFORT Open Rev. 2021;6(4):252–61.
[12] Liow MHL, Goh GS, Wong MK, et al. Computer navigation and robotics in total knee arthroplasty. EFORT Open Rev. 2016;1(5):184–90.
[13] Siebert W, Mai S, Kober R, Heeckt PF. Technique and first clinical results of robot-assisted total knee replacement. Knee. 2002;9(3):173–80.
[14] Yang WY, Tsai TY, Wu CC, et al. Short-term clinical and radiographic outcomes of robotic-assisted versus conventional total knee arthroplasty: A meta-analysis of randomized controlled trials. J Clin Med. 2021;10(9):1981.
[15] Bellemans J, Vandenneucker H, Vanlauwe J. Robotic-assisted TKA: has the time come? Knee. 2012;19(6):485–6.
[16] Cool CL, Michalski MP, Dombrowski ME, et al. Cost analysis of robotic-arm assisted total knee arthroplasty. J Am Acad Orthop Surg. 2020;28(18):e803–9.
[17] Sodhi N, Khlopas A, Piuzzi NS, et al. The learning curve for robotic-assisted total knee arthroplasty: a single-surgeon early experience. J Knee Surg. 2018;31(1):17–21.
[18] Page MJ, McKenzie JE, Bossuyt PM, et al. The PRISMA 2020 statement: An updated guideline for reporting systematic reviews. BMJ. 2021;372:n71.
[19] Wan X, Wang W, Liu J, Tong T. Estimating the sample mean and standard deviation from the sample size, median, range and/or interquartile range. BMC Med Res Methodol. 2014;14:135.
[20] Higgins JP, Thompson SG, Deeks JJ, Altman DG. Measuring inconsistency in meta-analyses. BMJ. 2003;327(7414):557–560.
[21] Guyatt GH, Oxman AD, Vist GE, et al. GRADE: An emerging consensus on rating quality of evidence and strength of recommendations. BMJ. 2008;336(7650):924–926.
[22] Ritter MA, Davis KE, Meding JB, Pierson JL, Berend ME, Malinzak RA. The effect of alignment and BMI on failure of total knee replacement. J Bone Joint Surg Am. 2011;93(17):1588–96.
[23] Parratte S, Pagnano MW, Trousdale RT, Berry DJ. Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. J Bone Joint Surg Am. 2010;92(12):2143–9.
[24] Parratte S, Pagnano MW, Trousdale RT, Berry DJ. Effect of alignment on TKA longevity. J Bone Joint Surg Am. 2010;92(10):2143–2149.
[25] Bellemans J. Neutral mechanical alignment: has it been overvalued? J Arthroplasty. 2013;28(5):675–680.
[26] Baker PN, Petheram T, Jameson SS, et al. Component malalignment and failure rates in UK National Joint Registry. Bone Joint J. 2012;94-B(8):1023–1029.
[27] Kayani B, Konan S, Pietrzak JRT, Haddad FS. Robotic technology in TKA: current concepts. Bone Joint J. 2019;101-B(7):845–852.
[28] Sodhi N, Khlopas A, Piuzzi NS, et al. Does obesity influence robotic outcomes? J Arthroplasty. 2018;33(9):2959–2964.
[29] Clement ND, Weir DJ, Holland JP, Gerrand CH. MCID in KOOS scores. J Orthop Res. 2018;36(2):573–580.
[30] Sires J, Wilson M, O’Donnell D. Robotic TKA and soft tissue preservation. J Knee Surg. 2021;34(2):176–182.
[31] Chinzei N, Hiranaka T, Fukuda A, et al. Functional parity by 2 years post-TKA. J Orthop Surg. 2020;28(1):1–8.
[32] Kamath AF, Courtney PM, Lee GC. Satisfaction rates in robotic vs manual TKA. Clin Orthop Relat Res. 2019;477(1):108–115.
[33] Kayani B, Tahmassebi J, Konan S, et al. Learning curve for robotic-assisted TKA. Bone Joint J. 2019;101-B(10):1400–1409.
[34] Namba RS, Paxton L, Fithian DC, Stone ML. Infection risk and operative time. J Bone Joint Surg Am. 2005;87(8):1776–1781.
[35] Pearle AD, Kendoff D, Musahl V. Role of robotics in resident training. J Bone Joint Surg Am. 2010;92(Suppl 1 Pt 1):171–176.
[36] Mahure SA, Bosco JA. Safety of robotic knee arthroplasty. J Am Acad Orthop Surg. 2020;28(9):e388–e398.
[37] Marchand RC, Sodhi N, Anis HK, et al. CT-based vs imageless robotic TKA: a comparison. J Knee Surg. 2019;32(3):239–250.
[38] Cool CL, Sayeed Z, Orozco FR. Robotic TKA economics. J Arthroplasty. 2020;35(2):505–511.
[39] Moschetti WE, Cram P, et al. Cost-effectiveness of robotic TKA. J Bone Joint Surg Am. 2016;98(15):1340–1347.
[40] Hetaimish BM, Khan MM, Simunovic N, et al. Meta-analysis of robotic vs conventional TKA. J Arthroplasty. 2016;31(2):250–257.
[41] Liow MHL, Goh GS, Wong MK, Chin PL, Tay DK, Yeo SJ. Robotic-assisted total knee arthroplasty may lead to improvement in quality-of-life measures: a 2-year follow-up of a prospective randomized trial. Knee Surg Sports Traumatol Arthrosc. 2017 Sep;25(9):2942-51.
[42] Yang J, Wang L, Zhang C, et al. Updated meta-analysis of robotic-assisted TKA. Orthop Surg. 2022;14(1):81–91.


IJBMR -ISSN: 0976:6685. ©Copyright 2026 This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
Published by BioMedSciDirect Publications